The Effect of Cooling Water Mass Flow Rate Variations on the Heat Pipe Solar Collector Performance
DOI:
https://doi.org/10.31185/ejuow.Vol5.Iss2.56Keywords:
solar collector, flat plate, heat pipe, cooling water mass flow rateAbstract
The thermal performance of FPHPSC has been studied experimentally and theoretically. The collector consists of copper absorber plate, single glass cover, glass wool insulation and aluminum case. Ten wickless heat pipes of 12.7 mm inner diameter. The experimental studies of collector performance have been performed on four different CWMFR (0.03, 0.04, 0.05 and 0.06) kg/s. The relation between the amount of useful heat, instantaneous collector efficiency and solar intensity is discussed. The collector are tested under the climate condition of Kut city (32.6 latitude and 45.7 longitude). It is investigated that the increasing of CWMFR increase the efficiency of the collector. The percentage increase in the efficiency of the solar collector is in order of (13%), when the cooling water mas flow rate changes from 0.03 kg/sec to 0.06 kg/sec at (45o) collector tilt angle. A computer program based on VISUAL BASIC language (version 6) used for the theoretical analysis. The experimental results are in agreement reasonably with the theoretical predictions.
References
[2] Amir Faghri ,"Heat Pipes: Review, Opportunities and Challenges", Frontiers in heat pipes, 2014.
[3] Amir Faghri, "Heat Pipe Science and Technology", Taylor and Francis Group, First Edition, 1995.
[4] Barhim Taofik, Mihiri Foued and Jemni Abdlmajid,"Parametric Study of Flat Plate Wick Assisted Heat Pipe Solar Collector", Journal of solar Energy Engineering, Vol. 135, 2013.
[5] Facao J. and Oliveira A. C. “Simulation of the Thermal Behavior of a Hybrid Heat Pipe Solar Collector” 1st International Conference on Sustainable Energy Technologies, Porto, Portugal, 2002.
[6] Samual L. A., Sergio C., Jaco F. and Almeida D. "Experimental Investigation of the Thermal Performance of Two Phase Closed Thermosyphns with Addition of A Liquid Retention Structure in the Evaporator Region",13 th. International Heat Pipe Conference, 2004.
[7] Nada S.A., El-Ghetany H.H. and Hussein H.M.S., "Performance of a Two Phase Closed Thermosyphon Solar Collector with a Sheel and Tube Heat Exchanger", Applied Thermal Engineering, 2004. [8] Abede K.E. "Numerical Modeling and Experimental Validation of Heat Pipe Solar Collector for Water Heating" M.Sc. thesis, KTH School of Industrial Engineering and Management Energy technology, 2012.
[9] Jalal M. J., Sabah T.A. AND Ahmed H.J., "Study the Effect of variable condensers Length on Improving the Performance of a Heat Pipe Solar Collector", Advances in Natural and Applied Sciences, 2016.
[10] S.B. Riffat, X. Zhao, P.S. Doherrty, "Developing of a theoretical model to investigate thermal performance of a thin membrane heat pipe solar collector", Journal of Applied Thermal Engineering, pp. 899–915.
[11] Azad. "Theoretical and Experimental Investigation of Heat Pipe Solar Collector", Experimental Thermal and Fluid Science, 2008.
[12] H.C. Hottel, A. Willier, "Evaluation of flat plate solar collector performance, in: Transactions of the Conference on Solar Energy", Vol. II, Thermal Processes, University Arizona, pp. 74–104, 1955.
[13] M.W. Kays, A.C. London, "Compact Heat Exchanger Design", McGraw-Hill, New York, Third Edition, 1984.